Repeater VEGATEL VT5-900E works simultaneously in two frequency bands of 900 MHz and an extended range of E-GSM networks in the following standards: GSM-900, E-GSM (it works Megafon) and 3G (UMTS-900). Robust metal housing, designed for indoor use and production (protection class IP55). Automatic and manual gain control, overload protection and an intuitive display.
The output power of the repeater is one of the largest in its class (up to 37 dBm). Such power allows for increased cellular signal at the sites of various types:
- Open area (10 km2) *
- Low-rise buildings (up to 2 km2) *
- Production complexes (100 000 m2) *
MODEL FEATURES
- operates in the range of GSM-900
- has an automatic gain control to 20 dB and manual gain control up to 31 dB
- operates over a wide voltage range - from 90 to 264 V
- equipped with a power LED
- compact size, elegant appearance, low power consumption.
* - The area of the repeater depending on the level of the input signal parameters other components of cellular signal amplification system, wall material and other features of the building. Expand the coverage is possible by installing the antenna booster and / or booster VEGATEL.
PERFORMANCE
Working frequency GSM900 Phone - Station 890 ~ 915 MHz Station - phone 935 ~ 960 MHz
E-GSM900 Phone - Station 880 ~ 890 MHz Station - phone 925 ~ 935 MHz
Maximum gain Telephone - Station ≥ 85dB station - phone ≥ 90 dB
Phone Power Output - Station Station ≥ 20 dBm - 37 dBm ≥ phone
Manual gain control ≥ 31 dB (1 dB step)
Manual gain control ≥ 31 dB (1 dB step)
Automatic Gain Control: ≥ 20 dB
Noise figure of 6 dB ≤
Input VSWR ≤ 2
Group delay ≤ 1,5 ms
Frequency stability ≤ 0,01 ppm
LED1 Power LED
LED2 LED "Overload" (1-5 dB orange, red 15-20)
Impedance 50 ohms
Connector N-Female
Dimensions ustroysiva 280 x 460 x 270 mm
Carton Size 600 x 500 x 300 mm
Net weight of 15 kg
Gross weight of 16 kg
Input: ~ 90 - 264 (50 Hz), Output: 9 V / 8 A, 28 V / 10 A
Power Consumption 74 W
Protection from external factors, IP55
Cooling Natural cooling
Reduce the heat of operation from -25 ° C to +55 ° C
Reduce the heat storage from -40 ° C to +80 ° C
Humidity 5% to 85%
Atmospheric pressure of 86 kPa to 106 kPa